home *** CD-ROM | disk | FTP | other *** search
/ Night Owl 9 / Night Owl CD-ROM (NOPV9) (Night Owl Publisher) (1993).ISO / 032a / ast_93.zip / 0737.TB < prev    next >
Text File  |  1992-01-23  |  1KB  |  30 lines

  1. =============================================================================
  2.  
  3. AST RESEARCH, INC.         TECHNICAL BULLETIN #0737                  01-23-92
  4.  
  5. =============================================================================
  6.  
  7.  
  8.                     PREMIUM EXEC AND MICROSOFT PS/2 MOUSE
  9.  
  10.  
  11. Problems have been reported with some Microsoft PS/2 Serial and PS/2 Mice
  12. when attached to the mouse port of AST Premium Exec 386SX-20 and 386SX-25
  13. systems.  The mouse may exhibit either intermittent operation or a failure to
  14. initialize after executing the mouse driver.  This problem does not occur if
  15. the same mouse is attached to the Premium Exec's serial port.
  16.  
  17. The cause of the problem is that some Microsoft Mice release the clock and
  18. data lines too quickly when the system is first powered on.  The problem has
  19. been resolved on Premium Exec 386SX-20 systems with version 1.05 of the
  20. Keyboard BIOS and on Premium Exec 386SX/25 systems with version 1.15 System
  21. BIOS.
  22.  
  23. Premium Exec users experiencing this problem should contact an AST Authorized
  24. Service Center and obtain the following:
  25.  
  26.        PRODUCT                   DESCRIPTION           PART NUMBER
  27.  
  28.     Premium Exec 386SX-20    BIOS Upgrade 1.07/1.05    500892-001
  29.     Premium Exec 386SX-25    System BIOS 1.15          237838-005
  30.